What Is Solar Thermography?

Updated

Solar thermography is the use of an infrared camera to record temperature patterns on photovoltaic modules and related electrical equipment while the system is operating. A warmer cell, substring, module, or connection can point to a fault, to shade or soiling, or to an ordinary temperature gradient. The image is evidence to hand to a qualified person. It is not a diagnosis, and it is not a repair procedure.

Decision path for a solar infrared image: record the pattern, compare a visible photo and the sun, and hand the file to a qualified person.

A warm pattern is recorded, then compared with a visible photo and the sun, and the file goes to a qualified person rather than becoming a repair or a reason to open a combiner.

What an infrared camera records on an operating array

A photovoltaic cell turns part of absorbed sunlight into current and leaves the rest as heat. The Department of Energy’s performance basics, updated 5 May 2026, define conversion efficiency as that electrical share, and note that a hotter cell raises current slightly while cutting voltage by more. Even warming across the array on a bright day is ordinary. The survey is for places that do not match their neighbors.

The March 2018 Task 13 report from IEA PVPS, the photovoltaic power systems collaboration, explains why inactive areas usually look warmer. Some irradiance becomes direct-current power and leaves the module. Where conversion stops, that energy stays as heat. The report lists disconnected modules or strings, potential-induced degradation, shunted cells, and short-circuited bypass diodes. Those faults often make only a modest step that grows with irradiance, so a dull day can hide them. A hot spot from a poor connection or severe mismatch is a different pattern, and the report calls that kind usually easier to see.

The camera collects infrared radiation, including reflections from clouds, buildings, and sky. Software converts that signal only after emissivity, reflected temperature, and the air path are accounted for. The report states typical emissivity of 0.85 for glass and 0.95 for a polymer backsheet when the view stays within 90 to 60 degrees for glass and within 90 to 45 degrees for the polymer. Those ranges are not settings to copy onto another camera, angle, or module. A qualified person sets the actual measurement.

Sandia’s Regional Test Centers keep infrared inside a wider kit. Chambers in New Mexico and Louisiana combine it with electroluminescence and dark current-voltage tests. The Colorado center, at the National Laboratory of the Rockies’ outdoor test facility, pairs current testing with diagnostic imaging.

An image is evidence, not a diagnosis

The Task 13 report says a scan is meant to find trouble before output falls or materials are badly damaged. A warm mark does not prove output has already dropped. Strong local heat can hurt performance and, in extreme cases, lead to a fire. Infrared misses failures that do not heat the module. Electroluminescence, light emitted when current is forced through a cell, can show cracks a thermal image misses. The report treats the two methods as complementary.

The December 2018 operations report from the National Renewable Energy Laboratory, Sandia National Laboratories, the SunSpec Alliance, and an industry working group is hosted by the National Laboratory of the Rockies as NREL/TP-7A40-73822. Aerial thermal imaging, it says, can flag string, module, and sub-module faults, including hot spots and possible fire risks, and can stand in for manual electrical testing in annual preventive maintenance, or be used at commissioning, at warranty end, and on an alternating-current substation. Without processing checked against ground measurements, the flight shows symptoms and a rough location, not a diagnosis. Cell-level hot spots generally do not move output enough for data review alone to see them. String metering can still catch faults that change string current.

Hand the radiometric file, the visible photo, and the electrical map to a qualified person. Do not replace a module, open a combiner, or wash from the color scale. The same report says voltage, current, and current-voltage tests find only defects already causing significant failure, so they miss hot spots that are not yet cutting measurable output. Live combiner tests need arc-flash equipment, and for some layouts the hazard in its 2012 NFPA reference may rule out live work.

Patterns worth recording, and patterns that mislead

The Task 13 report groups the main abnormalities as hot cells, also called hot spots, from broken front glass, external shade, or problems inside the cell; heated bypass diodes in the junction box; heated string fuses; and heated direct-current or alternating-current cables and connections.

What shows up What it may relate to What it does not settle
One cell much warmer than its neighbors Cell or interconnect damage, or small shade Whether the cell failed, or whether output moved
A block of cells warmer together An active or shorted bypass diode, or an inactive substring Which part to change
A module or a run of modules warmer than the row An open module or string Whether the portal should already show it
A warm junction box, fuse, cable, or connector A connection heating under load Whether it can wait for the next visit
A smooth gradient, stronger near the edge Ordinary unevenness that grows with irradiance A defect list

Shade is the common false lead. The report shows hot cells from a rod, plants, medium-voltage equipment, and a neighboring row, so pair each thermal frame with a visible photo and the sun position. Record a warm connector and leave the next look to a qualified electrical worker. Broken glass after hail can sit next to hot cells, and a survey can mark candidates without proving a warranty claim. Half-cut cells, different diode layouts, and module-level electronics can change the picture relative to the 2017 and 2018 examples.

Conditions, cameras, and the specification that sets a method

The Task 13 report requires stable weather. A typical module takes 5 to 15 minutes to settle after a change in irradiance, air temperature, or wind. Passing clouds both move the sun and reflect in the glass. The report recommends images above 600 W/m2, with no clouds, low wind, and stable air temperature. Natural unevenness of up to 8 K can show up as a gradient. A step along a cell, substring, or module is more suggestive of a defect. Its simplified heat balance looks for more than 2.5 K between active and inactive areas. Those figures describe a visible contrast. They are not a shutdown rule.

The report says those specifications describe a procedure and are not meant to set pass/fail criteria. As of 22 November 2026, the IEC catalog still lists IEC TS 62446-3:2017, edition 1.0, published 15 June 2017, stability date 2026. The abstract covers outdoor infrared inspection of operating modules and plants: equipment, ambient conditions, procedure, the inspection report, personnel qualification, and a matrix of thermal abnormalities as a guideline, for fire protection, production availability, and module quality. Task 13 adds cables, fuses, switches, and inverters to that scope. A separate module-thermography draft was for the lab or the production line, not a field rule this page treats as in force. The stability date does not prove a newer edition, and the sources opened here do not show Maryland, Virginia, the District of Columbia, or federal law adopting the specification. A contract or insurer may still name an edition. Confirm that with the authority having jurisdiction.

The 2018 report also quotes a 2016 communique: thermal sensitivity under 0.02°C, integration under 2 ms, thermal resolution of 19 cm per pixel or better, visible resolution of 3 cm per pixel or better, irradiance of at least 600 W/m2, irradiance change under 100 W/m2, and temperature change under 5°C. Those figures belong to that proposal. This page did not read them in IEC TS 62446-3, and they are not a flight height or an emissivity to copy. Handheld and airborne work, the Task 13 report adds, use different lenses and distances, and no single matrix picks a camera class.

Handheld surveys, aerial surveys, and the electrical layout

The 2018 report allows a manned aircraft or an unmanned aerial vehicle. Under ideal conditions, the Task 13 report’s example puts a handheld pass at about 15 to 20 hours and a drone pass at about 5 to 10 hours for a plant of 4 MWp nominal power. That comparison is not a local schedule. Images with no string map still leave the electrical follow-up undone.

Wiring changes what one warm module means. The Department of Energy’s inverter overview, updated 31 March 2025, separates central, string, and microinverter layouts. Shade or damage on one panel can cut a whole string on a string inverter. A microinverter on each panel keeps that panel from reducing what the others can deliver. A hot cell can still be a safety or warranty issue in either layout. The single-line or string map, not the color scale, shows which case this is.

Aircraft rules are separate from image quality. 14 CFR Part 107, as the eCFR showed it through 19 November 2026 and as read on 22 November 2026, covers civil small unmanned aircraft. Recheck that continuously updated text before a flight. Section 107.3 sets the line at under 55 pounds at takeoff, attachments included. Section 107.12 requires a remote pilot certificate, or immediate control by someone who holds one. Section 107.31 requires visual line of sight, unaided except by corrective lenses. Section 107.51 caps groundspeed at 87 knots (100 miles per hour) and altitude at 400 feet above the ground, unless the aircraft stays inside a 400-foot radius of a structure and no higher than 400 feet above its top, with at least 3 statute miles of visibility, 500 feet below cloud, and 2,000 feet horizontally from cloud. Section 107.41 requires air-traffic authorization in Class B, C, or D and in surface Class E at an airport. Section 107.39 limits flight over people. Sections 107.200 and 107.205 allow a waiver only if the FAA finds the operation safe. Those altitudes are legal limits, not a height chosen so a cell will resolve. A roof walk still needs someone qualified for that roof.

What to name before anyone flies or climbs

Commissioning, warranty end, a storm, an inverter that trails its neighbors, and a routine visit are different jobs. The 2018 sample schedule lists an annual infrared check for hot spots and bypass-diode failure and leaves the module share and the combiners as blanks. Name the purpose, whether combiners and alternating-current gear are in scope, how irradiance and wind will be recorded, and whether the deliverable is a radiometric file plus a visible photo and a module identifier. State which electrical tests are included and, for a drone, who holds the remote pilot certificate. The same report lists an American Society for Nondestructive Testing qualification and equipment calibration as items to consider. That list assigns no credential to any company. Soleil’s guide to commercial solar operations and maintenance places an infrared line beside other maintenance tasks and separates preventive work from later repairs.

An illustrative roof, not a project record

This illustrative warehouse is not a Soleil Energy project and not a measured site. Three inverters share one array. On clear afternoons one inverter trails the other two, which track each other. A survey during production shows three pictures. One string has a warmer block in a substring shape. Another string has a single hot cell, and the visible photo shows a vent-pipe shadow on that cell at that hour. One combiner connector is warmer than its neighbors.

No picture names a part to buy. Pass the string map along with the radiometric image, the visible photo, the location, and that hour’s irradiance, wind, and monitoring export. The substring shape raises a diode or open-substring question. Compare the shadow with the sun path before anyone calls the cell failed. The connector is energized equipment, not a washing task.

If the portal is blank, do not start with infrared. The passive outdoor method in IEC TS 62446-3 needs the array running in the sun. Soleil’s notes on a system that is not producing and on monitoring that has gone offline separate a real production drop from a stale or dark portal. A finished survey can narrow which combiners to open. It does not approve an interconnection or satisfy a performance test unless the contract says so, and aerial imaging at commissioning in the 2018 report does not replace a utility’s own tests. Price the survey apart from any later repair, and say so if a battery or charger shares the site.

Questions before you order a survey

Does a warm module have to be replaced?

No. The Task 13 report says an infrared finding does not inevitably mean output has already fallen, and shade can imitate a fault. Strong local heat can still justify a prompt look because of fire risk in extreme cases. Replacement depends on tests a qualified person chooses and on the written warranty.

Can monitoring replace the survey?

Not for cell-level hot spots. The 2018 report says those often do not move output enough to see in data review, while string metering can show faults that change string current. Use the portal to choose whether a survey is worth ordering, and the survey for the map the portal cannot draw.

Is a drone survey allowed over a commercial roof?

Only if that flight meets the rules that apply to it. The Part 107 points above are a baseline, not a permit. A roof near an airport, or one with people on it, can fail them. The pilot confirms the current text. This page is not an authorization.

When is electroluminescence the better next test?

When the question is cracks or other damage that may not heat the glass. The Task 13 report says electroluminescence can sort production, handling, and field damage, while infrared misses failures that stay cool. It usually needs darkness or a special daylight setup. Many decisions still need both images plus an electrical test.

What should you bring to a maintenance conversation?

Bring models, a string map or single-line if you have one, exports from the odd days, storm dates, and the warranty language. If images exist, bring radiometric files and the weather notes. The person assessing the system still has to see the site.

Bring the file to someone who can test the cause

Soleil Energy’s monitoring and operations service covers performance monitoring, preventive maintenance, and fault diagnosis, including systems the company did not install. Soleil Energy describes its service area as Maryland, Northern Virginia, and Washington, DC. An assessment can start from the equipment list, the fault history, and any infrared images already in hand. It does not treat a thermal picture as a substitute for site work, and it does not commit Soleil Energy to repair every finding.

Project requirements depend on the site, equipment and applicable rules. Confirm design and installation decisions with the appropriate qualified professional.